Pickup currently not available
Key Features:
-
Integrated UHPLC-QTOF System: Seamlessly combines the Bruker Impact II Q-TOF with Bruker Elute UHPLC for an optimized, high-resolution LC-MS/MS workflow.
-
High Resolution & Accuracy: Resolution up to 50,000 FWHM with <1 ppm mass accuracy for confident compound identification.
-
Ultra-Fast Acquisition: Spectral acquisition speeds up to 50 Hz, supporting rapid UHPLC separations.
-
True Isotopic Fidelity (TIF): Accurate isotopic pattern matching for robust formula confirmation.
-
High Dynamic Range: More than 5 orders of magnitude dynamic range, suitable for both trace analytes and abundant species.
-
Elute UHPLC Performance: Supports pressures up to 1300 bar, with flexible column choices for sharp peak resolution and robust chromatographic performance.
-
Versatile Ion Sources: ESI, nanoESI, APCI, and APPI ionization options for broad application coverage.
-
Advanced Data Processing: Integrated with Compass DataAnalysis, MetaboScape, ProteinScape, and BioPharma Compass for comprehensive analysis.
-
Regulatory Compliance: 21 CFR Part 11 ready for use in regulated labs.
-
Robustness & Reliability: Built for high-throughput environments with consistent performance and reduced downtime.
Applications:
-
Proteomics & Biopharma: Peptide/protein identification, post-translational modification (PTM) mapping, monoclonal antibody (mAb) analysis.
-
Metabolomics & Lipidomics: Untargeted metabolite profiling, biomarker discovery, lipid pathway analysis.
-
Pharmaceutical Analysis: Drug discovery, metabolite identification, pharmacokinetics (PK), impurity profiling.
-
Food Safety & Environmental: Detection of pesticides, contaminants, toxins, and residues with high sensitivity.
-
Clinical & Translational Research: Biomarker validation, personalized medicine, disease mechanism studies.
Specifications (Table):
| Parameter | Specification |
|---|---|
| MS Type | Quadrupole Time-of-Flight (QTOF) |
| Mass Range | m/z 50 – 20,000 |
| Resolution | Up to 50,000 FWHM |
| Mass Accuracy | <1 ppm (internal calibration) |
| Acquisition Speed | Up to 50 Hz |
| Dynamic Range | >5 orders of magnitude |
| UHPLC System | Bruker Elute UHPLC (1300 bar, sub-2 µm columns) |
| Ionization Sources | ESI, nanoESI, APCI, APPI |
| Fragmentation Modes | CID (Collision-Induced Dissociation) |
| Software | Compass DataAnalysis, MetaboScape, ProteinScape, BioPharma Compass |
| Compliance | 21 CFR Part 11 ready |
| Detector Technology | True Isotopic Fidelity (TIF) with SmartBeam-II detection |