Pickup currently not available
Key Features:
-
Integrated High-Performance System: Combines the Bruker Impact II Q-TOF with Agilent 1290 Infinity II UHPLC for robust LC-MS/MS workflows.
-
High Resolution: Provides up to 50,000 FWHM resolution with <1 ppm mass accuracy for confident identification and quantitation.
-
Fast Acquisition: Achieves up to 50 Hz spectral acquisition, enabling compatibility with ultra-fast UHPLC gradients.
-
Superior Chromatography: Agilent 1290 Infinity II UHPLC delivers up to 1300 bar pressure with sub-2 µm particle columns for sharp separations.
-
True Isotopic Fidelity (TIF): Ensures accurate isotopic pattern recognition and reliable molecular formula confirmation.
-
High Dynamic Range: More than 5 orders of magnitude, supporting trace-level and high-abundance compound analysis.
-
Ionization Flexibility: ESI, nanoESI, APCI, and APPI for broad application coverage.
-
Data Processing Ecosystem: Compatible with Bruker Compass DataAnalysis, MetaboScape, ProteinScape, and BioPharma Compass software.
-
Regulatory Support: 21 CFR Part 11 ready, suitable for GxP and regulated pharmaceutical labs.
-
Robust Design: Reliable for long-term use in proteomics, metabolomics, pharma, and environmental applications.
Applications:
-
Proteomics & Biopharma: Peptide/protein identification, glycosylation studies, monoclonal antibody characterization, PTM analysis.
-
Metabolomics & Lipidomics: Comprehensive metabolite and lipid profiling, biomarker discovery, and pathway analysis.
-
Pharmaceutical Development: Drug discovery, metabolite identification, DMPK studies, impurity profiling.
-
Food & Environmental Testing: Monitoring of contaminants, pesticides, residues, and pollutants.
-
Clinical & Translational Research: Biomarker validation, disease mechanism exploration, personalized medicine studies.
Specifications (Table):
| Parameter | Specification |
|---|---|
| MS Type | Quadrupole Time-of-Flight (QTOF) |
| Mass Range | m/z 50 – 20,000 |
| Resolution | Up to 50,000 FWHM |
| Mass Accuracy | <1 ppm (internal calibration) |
| Acquisition Speed | Up to 50 Hz |
| Dynamic Range | >5 orders of magnitude |
| UHPLC System | Agilent 1290 Infinity II (1300 bar, sub-2 µm columns) |
| Ionization Sources | ESI, nanoESI, APCI, APPI |
| Fragmentation Modes | CID (Collision-Induced Dissociation) |
| Software | Compass DataAnalysis, MetaboScape, ProteinScape, BioPharma Compass |
| Compliance | 21 CFR Part 11 ready |
| Detector Technology | True Isotopic Fidelity (TIF), SmartBeam-II detection |