Key Features:
-
Compact, space-saving design for routine QA/QC and research laboratories.
-
Modular injectors and detectors allow fast tool-free exchange, minimizing downtime.
-
Advanced Electronic Flow Control (EFC) ensures precise carrier gas delivery and reproducibility.
-
Column oven with fast heating and cooling rates for improved throughput.
-
Flexible injector options: split/splitless, PTV, on-column, and large-volume injection.
-
Detector options: FID, TCD, ECD, NPD, FPD, and compatibility with Thermo MS detectors.
-
Compatibility with Thermo autosamplers (AI/AS 1310, TriPlus RSH, TriPlus 100 LS) for high automation.
-
Seamless integration with Thermo Scientific ISQ™ and TSQ™ mass spectrometers for GC/MS solutions.
-
Full control via Thermo Scientific Chromeleon™ Chromatography Data System (CDS).
-
Energy-efficient oven and intelligent standby modes reduce operational costs.
-
Intuitive user interface and plug-and-play modules simplify operation and serviceability.
-
Designed for high reliability in 24/7 routine analysis workflows.
Applications:
-
Environmental monitoring: air toxics, water pollutants, pesticides, and VOCs.
-
Food and beverage analysis: flavor compounds, contaminants, packaging residues.
-
Petrochemical and chemical industry: refinery gases, aromatics, solvents, hydrocarbons.
-
Pharmaceutical QC and R&D: residual solvents, stability testing, drug formulation analysis.
-
Forensic science: drug of abuse screening, arson residues, explosives analysis.
-
Industrial hygiene and workplace safety monitoring.
-
Materials science and polymers: additives, plasticizers, monomers.
Specifications:
| Parameter | Specification |
|---|---|
| GC Platform | Thermo Scientific TRACE™ 1300 GC System |
| Inlets | Split/Splitless, PTV, On-Column, Large-Volume |
| Detectors | FID, TCD, ECD, NPD, FPD, µECD, MS compatibility |
| Oven | Fast heating/cooling, programmable temperature ramps, high thermal stability |
| Flow Control | Advanced Electronic Flow Control (EFC), constant flow/pressure modes |
| Autosampler | AI/AS 1310, TriPlus RSH, TriPlus 100 LS autosamplers |
| Acquisition Modes | Full Scan, SIM (when coupled with MS), multi-signal acquisition |
| Dynamic Range | >10⁷ (with FID) |
| Vacuum System | Not applicable (standalone GC), MS configurations use turbomolecular pumps |
| Interface | GC/MS interface for EI, CI, and other ionization techniques |
| Software | Thermo Scientific Chromeleon™ CDS, TraceFinder™ |
| Compliance | 21 CFR Part 11 compliant with Chromeleon CDS |