Pickup currently not available
-
Key Features:
-
The Waters ACQUITY Bio Arc UPLC is a biopharma-optimized UPLC platform specifically engineered for protein, peptide, mAb, and biomolecule analysis.
-
Equipped with the Waters 2998 Photodiode Array (PDA) Detector, providing full spectral scanning (190–800 nm) for peak purity analysis, structural confirmation, and monitoring of biomolecular stability.
-
Features Arc Multi-flow path technology, enabling seamless method transfer from HPLC to UPLC without revalidation, ensuring reproducibility across analytical platforms.
-
Designed with bio-inert flow paths to minimize sample interaction, carryover, and metal ion binding—critical for sensitive biomolecule separations.
-
Compatible with Waters Protein-Pak, BEH, and other biopharma-focused UPLC columns for SEC, IEX, RP, and HILIC workflows.
-
Operates at pressures up to 9,500 psi (≈ 660 bar) for high-resolution biomolecule separations.
-
Integrated quaternary solvent delivery system supports complex gradients, including salt and pH-based bioseparations.
-
Column oven with thermal stability ensures consistent peak shapes for temperature-sensitive biomolecules.
-
Controlled by Waters Empower CDS, offering compliance-ready workflows with audit trails and full 21 CFR Part 11 support.
-
-
Applications:
-
Biopharmaceutical Analysis: mAb characterization, peptide mapping, glycoprotein profiling, biosimilar comparability studies.
-
Protein Chemistry: SEC for aggregation studies, RP for peptide analysis, IEX for charge variants.
-
Pharmaceutical QC: Assay, stability, and impurity profiling of therapeutic proteins and peptides.
-
Clinical Research: Biomarker analysis, proteomic screening, biotherapeutic monitoring.
-
Food & Nutraceuticals: Protein and amino acid profiling, detection of bioactive peptides.
-
Academic & Research Labs: Structural biology, biomolecule characterization, advanced separation science.
-
-
Specifications:
| Parameter | Specification |
|---|---|
| System Type | Bio-inert Ultra-High Performance Liquid Chromatography (UHPLC) |
| Pump | Quaternary solvent delivery, flow range 0.001–10 mL/min |
| Max Pressure | Up to 9,500 psi (≈ 660 bar) |
| Flow Path | Bio-inert design, minimal metal ion interaction |
| Autosampler | High-precision autosampler, injection range 1–100 µL, optimized for biomolecules |
| Column Oven | Temperature control (ambient +4 °C to 65 °C) |
| Detector (2998 PDA) | Photodiode Array Detector, 190–800 nm, spectral analysis & peak purity |
| Resolution | Optimized for SEC, IEX, RP, and HILIC workflows with biomolecules |
| Software | Waters Empower Chromatography Data System (CDS) |
| Compliance | GLP/GMP, 21 CFR Part 11 compliant |