Pickup currently not available
-
Key Features:
-
The Agilent 1260 Infinity II GPC/SEC System is a dedicated modular HPLC platform for polymer and biopolymer characterization.
-
Combines high-precision pumping, autosampler, thermostatted column compartment, and a high-sensitivity refractive index (RI) detector tailored for polymer applications.
-
Provides accurate molecular weight distribution determination and structural analysis of natural and synthetic polymers.
-
RI detector delivers exceptional baseline stability, low noise, and broad refractive index range, ideal for non-UV active analytes such as polymers.
-
Modular design allows flexible system configurations with additional detectors (UV, PDA, light scattering, viscometer).
-
Wide solvent compatibility ensures suitability for organic and aqueous GPC/SEC separations.
-
Fully integrated with Agilent OpenLab CDS software, supporting 21 CFR Part 11 compliance, data integrity, and audit trails.
-
System is optimized for robust, routine operation in QA/QC environments as well as advanced research.
-
Features excellent reproducibility with high-precision gradient formation and minimized delay volume.
-
-
Applications:
-
Polymer Industry: Molecular weight distribution of synthetic polymers, copolymers, and resins.
-
Biopolymers & Biopharma: Analysis of polysaccharides, glycoproteins, nucleic acids, and other biomacromolecules.
-
Pharmaceuticals: Formulation analysis of excipients, controlled-release polymers, PEGylated drugs.
-
Food & Nutrition: Carbohydrate and starch characterization.
-
Petrochemical Industry: Polymer additives, lubricants, and performance materials.
-
Academic & Research: Polymer chemistry, biopolymer structure studies, advanced SEC/GPC method development.
-
-
Specifications:
Parameter | Specification |
---|---|
System Type | Modular HPLC for GPC/SEC |
Pressure Rating | Up to 600 bar (8,700 psi) |
Flow Rate Range | 0.05–10.0 mL/min (precise flow control for polymer separations) |
Pump Type | Binary or quaternary gradient |
Autosampler | High precision, low carryover, variable injection volumes |
Column Oven | 4 °C above ambient to 85 °C with temperature stability ±0.1 °C |
Detector | High-sensitivity RI detector (baseline stability, wide refractive index range) |
Additional Detector Options | UV, PDA, multi-angle light scattering (MALS), viscometer |
Software | Agilent OpenLab CDS (GLP/GMP, 21 CFR Part 11 compliant) |
Applications | Molecular weight distribution, intrinsic viscosity, compositional analysis |
Compliance | GLP/GMP, 21 CFR Part 11 |