Pickup currently not available
Key Features:
-
Ultra-Sensitive Quantitation: Industry-leading LOQs for trace-level detection of small molecules, peptides, and metabolites.
-
iFunnel Technology: Improved ion capture and transmission efficiency, delivering superior ion currents for high sensitivity.
-
Dynamic Range: >6 orders of magnitude for quantitation of analytes across wide concentration ranges.
-
Fast Polarity Switching: <20 ms switching between positive and negative modes in a single run.
-
Advanced Collision Cell: LCID (linear collision cell with axial acceleration) for robust fragmentation and consistent quantitation.
-
High Throughput Data Acquisition: Supports >500 MRM transitions/sec to match UHPLC peak capacity.
-
Integrated with 1290 Infinity III UHPLC: State-of-the-art chromatography with up to 1300 bar pressure, ultra-low carryover, and superior injection precision.
-
MRM & Dynamic MRM (dMRM): Reduces noise and increases robustness in complex sample workflows.
-
Jet Stream ESI Source: Maximizes desolvation and ion focusing for better sensitivity and precision.
-
Regulatory Compliance: Full 21 CFR Part 11 support for secure data handling in GMP/GLP laboratories.
-
MassHunter Software Suite: Advanced quantitation, method optimization, compliance-ready reporting, and data integrity tools.
Applications:
-
Pharmaceutical R&D and QA/QC: Pharmacokinetics, DMPK, impurity profiling, and clinical bioanalysis.
-
Biopharmaceutical Analysis: Targeted peptide/protein quantitation, process monitoring, and stability studies.
-
Food Safety: Trace detection of pesticides, veterinary drugs, mycotoxins, contaminants, and authenticity testing.
-
Environmental Analysis: Emerging contaminants, endocrine disruptors, and pharmaceuticals in water, soil, and air.
-
Clinical & Forensic Toxicology: Screening and quantitation of drugs of abuse, metabolites, and toxicants.
-
Metabolomics & Lipidomics: Targeted quantitation of metabolites, lipids, and small molecules in biological research.
-
Regulated Laboratory Workflows: Designed for GLP/GMP labs requiring validated reporting and compliance.
Specifications (Table):
| Parameter | Specification |
|---|---|
| System Configuration | Agilent 6495D Triple Quadrupole LC/MS integrated with Agilent 1290 Infinity III UHPLC |
| MS Type | Triple Quadrupole LC/MS (LC-MS/MS) |
| Model | 6495D |
| Mass Range | m/z 10 – 3,000 |
| Resolution | Unit mass resolution (0.7 Da FWHM) |
| Dynamic Range | >6 orders of magnitude |
| Mass Accuracy | High reproducibility for quantitative assays |
| Ionization Modes | Agilent Jet Stream ESI, APCI, multimode |
| Polarity Switching | <20 ms |
| Acquisition Modes | MRM, dynamic MRM (dMRM), SIM |
| MRM Transition Speed | >500 transitions/sec |
| Sensitivity (LOQ) | Sub-femtogram levels (compound dependent) |
| Collision Cell | LCID with axial acceleration |
| Vacuum System | Dual turbo molecular pumps |
| UHPLC System | Agilent 1290 Infinity III UHPLC (up to 1300 bar, sub-2 µm columns, low carryover) |
| Autosampler | 1290 Infinity III autosampler with precision injection system |
| Interface | Orthogonal ESI with iFunnel technology |
| Software | Agilent MassHunter (method development, quantitation, audit trails, reporting) |
| Compliance | 21 CFR Part 11, GLP/GMP environments |