Pickup currently not available
Key Features:
-
12 Tesla Superconducting Magnet: Provides ultrahigh mass resolution (>10 million resolving power at m/z 400) for unrivaled molecular characterization.
-
Fourier Transform Ion Cyclotron Resonance (FT-ICR): Enables precise, accurate mass detection with sub-ppm mass accuracy.
-
eXtreme Resolution (XR) Mode: Achieves ultrahigh isotopic resolution, resolving isotopologues in complex mixtures.
-
Advanced Ion Optics & Detection: Optimized ion transfer and Bruker ParaCell® technology for high efficiency and accuracy.
-
Multiple Ionization Techniques: Supports ESI, MALDI, APCI, APPI, nano-ESI for broad application coverage.
-
MS/MS Capabilities: Electron Capture Dissociation (ECD), Collision-Induced Dissociation (CID), Infrared Multiphoton Dissociation (IRMPD), Electron Transfer Dissociation (ETD).
-
Top-Down Proteomics Ready: Precise intact protein analysis with post-translational modification (PTM) mapping.
-
Petroleomics Analysis: Characterization of thousands of hydrocarbons in crude oil with ultrahigh resolution.
-
Metabolomics & Lipidomics: Comprehensive profiling of complex biological mixtures at trace levels.
-
Software Ecosystem: Bruker Compass DataAnalysis, Bruker FTMS Control, and BioPharma Compass software.
-
Regulatory Compliance: 21 CFR Part 11 support for GMP/GLP environments.
Applications:
-
Proteomics: Top-down and bottom-up proteomics, PTM characterization, biomarker discovery.
-
Metabolomics & Lipidomics: Untargeted analysis of metabolites and lipids in biological systems.
-
Petroleomics: Ultrafine characterization of crude oil, asphaltenes, and petroleum fractions.
-
Environmental Analysis: Identification of complex organic pollutants and environmental contaminants.
-
Pharmaceutical Research: Impurity analysis, structural elucidation, and advanced drug development.
-
Complex Mixture Analysis: Resolving thousands of compounds simultaneously in biological, chemical, and environmental samples.
Specifications (Table):
Parameter | Specification |
---|---|
MS Type | Fourier Transform Ion Cyclotron Resonance (FT-ICR) MS |
Magnet Strength | 12 Tesla superconducting magnet |
Resolving Power | >10,000,000 at m/z 400 |
Mass Accuracy | <1 ppm with internal calibration |
Mass Range | Up to m/z 20,000 |
Ionization Sources | ESI, nanoESI, APCI, APPI, MALDI |
Fragmentation Modes | ECD, CID, IRMPD, ETD |
Acquisition Modes | Full Scan, MS/MS, high-resolution isotopic analysis |
Dynamic Range | >5 orders of magnitude |
Vacuum System | Ultra-high vacuum with multiple turbomolecular pumps |
Software | Bruker Compass FTMS, BioPharma Compass, DataAnalysis |
Compliance | 21 CFR Part 11 ready |