Pickup currently not available
Key Features:
-
Dual-Source Technology: Integrated MALDI-2 laser post-ionization with ESI (CaptiveSpray nanoESI), enabling both imaging MS and traditional LC-MS/MS in one system.
-
MALDI-2 Post-Ionization: Dramatically enhances ion yields for lipids, metabolites, glycans, and peptides in imaging workflows.
-
Trapped Ion Mobility Spectrometry (TIMS): Provides 4D molecular separation by retention time, m/z, intensity, and ion mobility.
-
QTOF High Resolution: Delivers >60,000 FWHM resolution with <1 ppm mass accuracy for reliable compound identification.
-
Versatile Workflows: Switch between spatial omics imaging and UHPLC-MS/MS proteomics on a single platform.
-
High Sensitivity: Detects low-abundance species with improved signal-to-noise from MALDI-2 ionization.
-
PASEF Support: When operated in LC-MS/MS mode, uses Parallel Accumulation Serial Fragmentation for ultra-fast proteomics.
-
Advanced Imaging: Enables molecular histology, lipidomics, drug distribution, and tumor microenvironment mapping.
-
Regulatory Ready: 21 CFR Part 11 compliant for pharmaceutical and clinical applications.
Applications:
-
Spatial Omics & Imaging Mass Spectrometry: High-resolution mapping of metabolites, lipids, peptides, and proteins in tissue.
-
Proteomics & Biomarker Discovery: PASEF-enabled high-throughput LC-MS/MS for deep proteome coverage.
-
Clinical & Translational Research: Mapping of disease biomarkers directly in tissue context.
-
Pharmaceutical R&D: Drug distribution and metabolism studies in tissue environments.
-
Metabolomics & Lipidomics: Enhanced MALDI-2 sensitivity for small molecule and lipid imaging.
-
Multi-Omics Integration: Combines imaging MS with proteomics for comprehensive biological insights.
Specifications (Table):
Parameter | Specification |
---|---|
MS Type | Dual-source TIMS-QTOF (MALDI-2 + ESI) |
Ion Mobility | Trapped Ion Mobility Spectrometry (TIMS) |
Special Technology | MALDI-2 post-ionization, PASEF for LC-MS/MS |
Mass Range | m/z 20 – 20,000 |
Resolution | >60,000 FWHM |
Mass Accuracy | <1 ppm (internal), <3 ppm (external) |
Acquisition Speed | >100 Hz with PASEF |
Ionization Sources | MALDI-2, CaptiveSpray nanoESI, APCI (optional) |
Laser System | Smartbeam™ 3D laser with MALDI-2 post-ionization |
Sample Types | Tissue sections, cell cultures, biofluids, LC-separated peptides/proteins |
Software | Bruker SCiLS Lab, Compass HyStar, ProteoScape, MaxQuant, Spectronaut |
Compliance | 21 CFR Part 11 ready |
Key Advantage | Single platform for MALDI imaging and high-resolution LC-MS/MS proteomics |