Pickup currently not available
Key Features:
-
Hybrid High-Resolution System: Combines Bruker timsTOF Pro QTOF with the industry-leading Agilent 1290 Infinity II UHPLC for ultra-fast, high-efficiency separations.
-
Trapped Ion Mobility Spectrometry (tims): Provides an orthogonal separation dimension, enabling 4D proteomics and resolving isomeric/structural variants.
-
PASEF Technology: (Parallel Accumulation Serial Fragmentation) achieves >100 Hz acquisition speeds with no sensitivity loss.
-
Ultra-Deep Proteome Coverage: Identifies thousands of proteins per run with high reproducibility.
-
Agilent 1290 Infinity II LC Benefits: Delivers ultra-high-pressure capacity (up to 1300 bar), low dispersion, precise gradient formation, and robust autosampling.
-
Quantitative Versatility: Supports label-free quantitation, DIA, PRM, and multiplexed labeling workflows.
-
High Sensitivity & Dynamic Range: Detects low-abundance biomarkers in complex biological samples.
-
Robust, Scalable Platform: Designed for 24/7 operation in pharmaceutical, clinical, and core proteomics facilities.
-
Comprehensive Software Integration: Compatible with Bruker ProteoScape, PEAKS, MaxQuant, Spectronaut, and Agilent MassHunter software for LC control.
-
Regulatory Compliance: Fully supports 21 CFR Part 11 and GxP workflows.
Applications:
-
Proteomics & Biomarker Discovery: Comprehensive peptide and protein identification.
-
Pharmaceutical R&D: Drug metabolism, PK/PD studies, and biotherapeutic characterization.
-
Clinical Research: Precision medicine and large-cohort proteomic studies.
-
Metabolomics & Lipidomics: Ion mobility-enhanced analysis of small molecules and lipids.
-
Food & Environmental Testing: Sensitive detection of contaminants and toxins.
-
Structural Biology: Protein folding and conformational studies via ion mobility separation.
Specifications (Table):
Parameter | Specification |
---|---|
MS Type | Trapped Ion Mobility (tims) Quadrupole Time-of-Flight (QTOF) |
Special Technology | PASEF (Parallel Accumulation Serial Fragmentation) |
Mass Range | m/z 20 – 20,000 |
Resolution | >60,000 FWHM |
Mass Accuracy | <1 ppm (internal), <3 ppm (external) |
Acquisition Speed | >100 Hz with PASEF |
Dynamic Range | >5 orders of magnitude |
Ion Mobility Range | 0.6–2.0 Vs/cm² (1/K₀) |
Ionization Sources | CaptiveSpray nanoESI, ESI, APCI (optional) |
LC System | Agilent 1290 Infinity II UHPLC (binary/quaternary pumps, autosampler, column oven, DAD) |
LC Pressure Capacity | Up to 1300 bar |
Vacuum System | Multi-stage turbo pumping system |
Software | Bruker Compass HyStar, ProteoScape, PEAKS, MaxQuant, Spectronaut, Agilent MassHunter (LC control) |
Compliance | 21 CFR Part 11 ready |
Key Advantage | Integrated 4D LC-MS/MS system with tims ion mobility and PASEF speed coupled to Agilent UHPLC power |