
Pickup currently not available
Key Features:
-
Integrated High-Performance Platform: Combines Bruker’s timsTOF Pro QTOF mass spectrometer with the Bruker Elute UHPLC for complete LC-MS/MS workflows.
-
Trapped Ion Mobility Spectrometry (tims): Adds an orthogonal separation dimension for precise differentiation of isomers and complex peptide mixtures.
-
PASEF Technology (Parallel Accumulation Serial Fragmentation): Boosts sequencing speed and sensitivity, enabling high proteome coverage.
-
High Resolution & Accuracy: Delivers >60,000 FWHM resolution and <1 ppm internal mass accuracy.
-
Elute UHPLC Advantages: Optimized for nano, micro, and analytical scale separations with superior gradient precision and reproducibility.
-
4D Proteomics Capability: Integration of ion mobility, retention time, mass-to-charge, and intensity for ultra-deep proteome analysis.
-
Quantitative Flexibility: Supports DIA, DDA, PRM, and label-free quantitation workflows.
-
Extended Dynamic Range: Captures both low-abundance biomarkers and high-intensity peptides.
-
Proven Robustness: Designed for continuous operation in high-throughput proteomics facilities.
-
Comprehensive Software: Compatible with ProteoScape, MaxQuant, PEAKS, and Spectronaut for end-to-end data analysis.
-
Regulatory Compliance: Supports 21 CFR Part 11 for GxP and pharmaceutical workflows.
Applications:
-
Proteomics Research: In-depth protein identification, biomarker discovery, and quantitative proteomics.
-
Clinical & Translational Studies: High-resolution proteome profiling for disease research.
-
Pharmaceutical Development: Biotherapeutics characterization, drug metabolism, and PK/PD studies.
-
Metabolomics & Lipidomics: High-resolution detection of small molecules and lipids with ion mobility separation.
-
Food & Environmental Testing: Detection of trace contaminants with high sensitivity.
-
High-Throughput Precision Medicine: Scalable workflows for large-cohort proteomic studies.
Specifications (Table):
Parameter | Specification |
---|---|
MS Type | Trapped Ion Mobility (tims) Quadrupole Time-of-Flight (QTOF) |
Special Technology | PASEF (Parallel Accumulation Serial Fragmentation) |
Mass Range | m/z 20 – 20,000 |
Resolution | >60,000 FWHM |
Mass Accuracy | <1 ppm (internal), <3 ppm (external) |
Acquisition Speed | >100 Hz with PASEF |
Dynamic Range | >5 orders of magnitude |
Ion Mobility Range | 0.6–2.0 Vs/cm² (1/K₀) |
Ionization Sources | CaptiveSpray nanoESI, ESI, APCI (optional) |
LC System | Bruker Elute UHPLC (nano, micro, and analytical configurations) |
Vacuum System | Multi-stage turbo pumping system |
Software | Bruker Compass HyStar, ProteoScape, MaxQuant, PEAKS, Spectronaut |
Compliance | 21 CFR Part 11 ready |
Key Advantage | Complete LC-MS/MS solution with Bruker Elute UHPLC integration |